HYDROLOGICAL REGIME AND HYDRAULIC CHARACTERISTICS OF THE DARYALYK MAIN COLLECTOR SYSTEM (KHOREZM REGION, UZBEKISTAN): LONG-TERM RECORDS AND FIELD FLOW MEASUREMENTS
Keywords:
drainage collector, discharge, acoustic Doppler current profiler, hydraulic resistance, clamp-on ultrasonic flowmeter, Khorezm, Amu Darya basinAbstract
The Daryalyk main collector system conveys saline drainage water and return flow from five districts of the Khorezm region (Uzbekistan) across the state border to Turkmenistan. Quantitative information on its flow regime and hydraulic behaviour is needed for planning cleaning, reconstruction and possible reuse of drainage water. This study combined (i) a 21-year record (2004–2024) of mean annual discharge, runoff and mineralization; (ii) frequency analysis of mean annual discharge with the Pearson Type III distribution; (iii) acoustic Doppler (SonTek S5, GPS-aided) discharge measurements at five cross-sections; (iv) hydraulic-resistance experiments on three 150 m reaches of the Divankul collector; and (v) clamp-on ultrasonic flow measurements in the pressure pipes of five pumping stations, complemented by 2021–2024 records of pumped volume and electricity use. Mean annual discharge was 22.98 m3/s (Cv = 0.35, Cs = 0.27; range 8.91–41.54 m3/s) and mean mineralization was 2.12 g/L (1.66–3.16 g/L). Discharges exceeded in 50, 75 and 96% of years were 22.6, 17.4 and 9.7 m3/s. Mean discharge in 2018–2024 (17.6 m3/s) was about 31% lower than in 2004–2017 (25.7 m3/s), although the trend was not statistically significant. Measured discharge decreased from 52.8 m3/s at the border cross-section to 1.6 m3/s in the uppermost one. In three Divankul reaches, Reynolds numbers of 3.4–3.8 × 105 indicated fully turbulent flow, and water-surface slopes of 1.1–1.5 × 10−3 at velocities of 0.32–0.36 m/s implied very high flow resistance (Manning’s n ≈ 0.11–0.13). The pumps delivered 85–95% of their design discharge of 0.5 m3/s. Pumped volume in Gurlan district fell from 3.62 to 0.15 million m3 between 2021 and 2024 at an almost constant 0.078 kWh/m3. The results give a quantitative basis for prioritising cleaning and for assessing the performance of water-lifting installations on the collector system.References
1. Chow, V.T. (1959). Open-Channel Hydraulics. McGraw-Hill, New York.
2. Cunnane, C. (1978). Unbiased plotting positions – a review. Journal of Hydrology, 37(3–4), 205–222. https://doi.org/10.1016/0022-1694(78)90017-3
3. England, J.F., Jr., Cohn, T.A., Faber, B.A., Stedinger, J.R., Thomas, W.O., Jr., Veilleux, A.G., Kiang, J.E., Mason, R.R., Jr. (2018). Guidelines for determining flood flow frequency – Bulletin 17C (ver. 1.1, May 2019). U.S. Geological Survey Techniques and Methods, book 4, chap. B5, 148 p. https://doi.org/10.3133/tm4B5
4. Ibrakhimov, M., Khamzina, A., Forkutsa, I., Paluasheva, G., Lamers, J.P.A., Tischbein, B., Vlek, P.L.G., Martius, C. (2007). Groundwater table and salinity: spatial and temporal distribution and influence on soil salinization in Khorezm region (Uzbekistan, Aral Sea Basin). Irrigation and Drainage Systems, 21(3–4), 219–236. https://doi.org/10.1007/s10795-007-9033-3
5. Ibrakhimov, M., Martius, C., Lamers, J.P.A., Tischbein, B. (2011). The dynamics of groundwater table and salinity over 17 years in Khorezm. Agricultural Water Management, 101(1), 52–61.
6. ISO 6416:2017. Hydrometry – Measurement of discharge by the ultrasonic transit time (time of flight) method. International Organization for Standardization, Geneva.
7. Mueller, D.S., Wagner, C.R., Rehmel, M.S., Oberg, K.A., Rainville, F. (2013). Measuring discharge with acoustic Doppler current profilers from a moving boat (ver. 2.0, December 2013). U.S. Geological Survey Techniques and Methods 3-A22, 95 p. https://doi.org/10.3133/tm3A22
8. Nepf, H.M. (2012). Flow and transport in regions with aquatic vegetation. Annual Review of Fluid Mechanics, 44, 123–142. https://doi.org/10.1146/annurev-fluid-120710-101048
9. Oberg, K., Mueller, D.S. (2007). Validation of streamflow measurements made with acoustic Doppler current profilers. Journal of Hydraulic Engineering, 133(12), 1421–1432. https://doi.org/10.1061/(ASCE)0733-9429(2007)133:12(1421)
10. Orlovsky, L., Matsrafi, O., Orlovsky, N., Kouznetsov, M. (2014). Sarykamysh Lake: collector of drainage water – the past, the present, and the future. In: Zonn, I.S., Kostianoy, A.G. (eds) The Turkmen Lake Altyn Asyr and Water Resources in Turkmenistan. The Handbook of Environmental Chemistry, vol. 28. Springer, Berlin, Heidelberg, pp. 107–140. https://doi.org/10.1007/698_2012_191
11. Simões, C., Ribeiro, Á.S., Almeida, M.C., Covas, D. (2024). Traceability and measurement uncertainty of non-removable field flowmeters using clamp-on ultrasonic flowmeters as reference. Acta IMEKO, 13(3), 1–6. https://doi.org/10.21014/actaimeko.v13i3.1777
12. Tischbein, B., Awan, U.K., Abdullaev, I., Bobojonov, I., Conrad, C., Jabborov, H., Forkutsa, I., Ibrakhimov, M., Poluasheva, G. (2012). Water management in Khorezm: current situation and options for improvement (hydrological perspective). In: Martius, C., Rudenko, I., Lamers, J.P.A., Vlek, P.L.G. (eds) Cotton, Water, Salts and Soums: Economic and Ecological Restructuring in Khorezm, Uzbekistan. Springer, Dordrecht, pp. 69–92. https://doi.org/10.1007/978-94-007-1963-7_5
13. University of Nebraska–Lincoln Extension (2008). Using ultrasonic flow meters in irrigation applications. NebGuide G1426 (revised March 2008). University of Nebraska–Lincoln, Lincoln, NE.